Ready to use with all PosiTector Shore Hardness Durometers
Fitted with replaceable Shore A or Shore D Targets to protect probe tips
Shore Hardness Durometer Accuracy Verification Kit
The DeFelsko SHDVERIFY PosiTector SHD Verifier, Shore Hardness Durometer Accuracy Verification Kit is ideal for checking the accuracy and operation of Shore hardness durometers and an important component in fulfilling both ISO and in-house quality control requirements. The PosiTector SHD Verifier and the included documents allow the user to certify the accuracy of PosiTector SHD Shore Hardness Durometers in-house.
- High precision load cell and handheld smart sensor indicator verifies PosiTector SHD Shore A and Shore D durometers
- Ready to use with all PosiTector SHD Shore Hardness Durometers
- Precise load control with micrometer adjustable stage
- Ideal for field or laboratory use

Kit Contents

- DeFelsko SHDVERIFY PosiTector SHD Verifier
- Load Cell
- Smart Sensor indicator
- Built-in rechargeable Lithium Ion batteries
- Universal AC adaptor
- Replaceable Shore A (aluminum)
- Shore D (brass) targets
- Allen wrench
- Instructions
- Sample Certificate of Accuracy
- Hard Shell Carrying Case
- Two Certificates of Calibration traceable to NIST
- One (1) year warranty
|  |

Features

Simple
- Ready to use with all PosiTector Shore Hardness Durometers
- Comes with a Sample Certificate of Accuracy
- Certificates of Calibration showing traceability to NIST included for both the load cell and smart sensor indicator
Durable
- Fitted with replaceable Shore A or Shore D Targets to protect probe tips
- Ideal for field or laboratory use
- Portable requires no external power source
- One year warranty
Accurate
- High precision load cell and handheld smart sensor indicator verifies PosiTector SHD Shore A and Shore D durometers
- Precise load control with micrometer adjustable stage

Specifications

Range | 0 - 10 |
Resolition | .001lb |
Accuracy | 0.004 lbs, ( 17.8 mN), ( 0.04 Shore D), ( 0.238 Shore A) |

Easy Operation

- Insert the appropriate Target (Shore A or Shore D) into the load cell.
- Connect the Shore Hardness Probe to the PosiTector SHD Verifiers Loading Fixture using the supplied Allen wrench.
- Apply pressure using the micrometer adjustable stage.
- Compare values from the durometer and the Verifier.
Downloads
F.A.Q.
What is the purpose of the PosiTector SHD Verifier
The PosiTector SHD Verifier is used to check the accuracy and operation of PosiTector SHD Shore durometers and is an important component in fulfilling both ISO and in-house quality control requirements. Contracts often specify that tests be performed with instruments that have measurement accuracy traceable to a National Metrology Institute such as NIST.
Are there different models of PosiTector SHD Verifier to choose from
No, there is only one model. The PosiTector SHD Verifier includes everything required for use with all PosiTector SHD models.
Can the PosiTector SHD Verifier be used with other manufacturers durometers
No, not without modification to the probe fixture to properly attach other manufacturers durometers.
What is the recommended Calibration Interval for the PosiTector SHD Verifier itself
We recommend customers begin their calibration intervals based on the recalibration date printed onthe Certificates of Calibration for the load cell and smart sensor indicator.